Buscar
Mostrando ítems 1-10 de 244
Esophageal transit time assessed by magnetic methods: An in vitro feasibility study of the novel alternating current biosusceptometry with 3-axis magnetorresistor
(2013-04-16)
A hybrid magnetic instrumentation to detect a magnetic field from a permanent magnet, and to detect magnetic markers and tracers using alternating current biosusceptometry (ACB) is discussed. The instrument was used to in ...
Esophageal transit time assessed by magnetic methods: An in vitro feasibility study of the novel alternating current biosusceptometry with 3-axis magnetorresistor
(2013-04-16)
A hybrid magnetic instrumentation to detect a magnetic field from a permanent magnet, and to detect magnetic markers and tracers using alternating current biosusceptometry (ACB) is discussed. The instrument was used to in ...
Pharmaceutical applications of AC Biosusceptometry
(Elsevier B.V., 2010-01-01)
AC Biosusceptometry offers an alternative to investigate noninvasively and without ionizing radiation the behavior of solid dosage forms in vitro and in the human gastrointestinal tract. This versatility allowed applying ...
Pharmaceutical applications of AC Biosusceptometry
(Elsevier B.V., 2010-01-01)
AC Biosusceptometry offers an alternative to investigate noninvasively and without ionizing radiation the behavior of solid dosage forms in vitro and in the human gastrointestinal tract. This versatility allowed applying ...
Disintegration of magnetic tablets in human stomach evaluated by alternate current Biosusceptometry
(Elsevier B.V., 2003-11-01)
Oral administration is the most convenient route for drug therapy. The knowledge of the gastrointestinal transit and specific site for drug delivery is a prerequisite for development of dosage forms. The aim of this work ...
Disintegration of magnetic tablets in human stomach evaluated by alternate current Biosusceptometry
(Elsevier B.V., 2003-11-01)
Oral administration is the most convenient route for drug therapy. The knowledge of the gastrointestinal transit and specific site for drug delivery is a prerequisite for development of dosage forms. The aim of this work ...
Disintegration of magnetic tablets in human stomach evaluated by alternate current biosusceptometry
(European Journal Of Pharmaceutics And Biopharmaceutics : Official Journal Of Arbeitsgemeinschaft Für Pharmazeutische Verfahrenstechnik E.v, 2003)
Oral administration is the most convenient route for drug therapy. The knowledge of the gastrointestinal transit and specific site for drug delivery is a prerequisite for development of dosage forms. The aim of this work ...
Disintegration of magnetic tablets in human stomach evaluated by alternate current Biosusceptometry
(2003-01-01)
Oral administration is the most convenient route for drug therapy. The knowledge of the gastrointestinal transit and specific site for drug delivery is a prerequisite for development of dosage forms. The aim of this work ...
Gastrointestinal transit and disintegration of enteric coated magnetic tablets assessed by ac biosusceptometry
(Elsevier B.V., 2006-01-01)
The oral administration is a common route in the drug therapy and the solid pharmaceutical forms are widely used. Although much about the performance of these formulations can be learned from in vitro studies using ...