Search
Now showing items 1-10 of 81
Unsuccessful treatment of atrophic mandible fracture by use of improper materials
(2016-01-01)
Fractures of atrophic mandibles are present on the day by day of buccomaxillofacial surgeons. Mandible atrophy occurs due to tooth loss, which over time induces bone resorption leading to a fragile and susceptible to ...
Effect of the number of screws on the stability of locking mandibular reconstruction plates
(2013-03-25)
Atrophic mandible fractures are frequently a challenge to stabilize. This study evaluated, through mechanical testing in vitro, the number of locking screws that is sufficient to withstand loading when applied with a locking ...
Effect of the number of screws on the stability of locking mandibular reconstruction plates
(2013-03-25)
Atrophic mandible fractures are frequently a challenge to stabilize. This study evaluated, through mechanical testing in vitro, the number of locking screws that is sufficient to withstand loading when applied with a locking ...
Implant-supported rehabilitation after treatment of atrophic mandibular fractures: report of two cases
(2015)
Objective The objective of this article is to present options of rehabilitation with dental implants in two cases of severely atrophic mandibles (<10 mm) after rigid internal fixation of fractures. Patients and method Two ...
Success rate of short unitary implants installed in atrophic mandible: Integrative Review
(2022-04-04)
Introduction: In the rehabilitation of total edentulous patients, lack of bone availability in posterior maxillary regions is common due to pneumatization of the maxillary sinus and posterior mandible due to the presence ...
Treatment of Atrophic Mandibular Fractures with the Pencilboneplate: Report of 2 Cases
(2012)
The incidence of fractures of the atrophic edentulous mandible is still low, even with the increasing life expectancy. The reduced blood supply of the sclerotic bone, the diminished contact area between bone ...
Failure of miniplate osteosynthesis for the management of atrophic mandibular fracture
(2013-07-01)
Fractures of the severely atrophic (<10 mm) edentulous mandible are not common, and these fractures with a vertical height of 10 mm or less have long been recognized as being particularly problematic. Although there are ...
Failure of miniplate osteosynthesis for the management of atrophic mandibular fracture
(2013-07-01)
Fractures of the severely atrophic (<10 mm) edentulous mandible are not common, and these fractures with a vertical height of 10 mm or less have long been recognized as being particularly problematic. Although there are ...