Buscar
Mostrando ítems 1-10 de 41
Pro-osteoclastic in vitro effect of Polyethylene-like nanoparticles: Involvement in the pathogenesis of implant aseptic loosening
(John Wiley and Sons Inc., 2016)
Polyethylene micro-sized wear particles released from orthopaedic implants promote inflammation and osteolysis; however, less is known about the bioactivity of polyethylene nano-sized wear particles released from the last ...
Orthopaedic implant failure: Aseptic implant loosening - the contribution and future challenges of mouse models in translational research
(Portland Press Ltd, 2015)
Aseptic loosening induced by UHMWPE wear particles is considered the main cause of longterm implant failure in orthopaedic surgery. The current therapy consists of surgical revision
and implant replacement, carrying severe ...
Does Patient-Specific Instrumentation Have a Higher Rate of Early Osteolysis Than Standard Referencing Techniques in Total Ankle Arthroplasty? A Radiographic Analysis
(SAGE, 2020)
INTRODUCTION:
Patient-specific instrumentation (PSI) has been developed for total ankle arthroplasty (TAA), with proven benefits. One concern regarding PSI is the need for more soft tissue dissection in order to accurately ...
Aseptic Loosening of Total Hip Arthroplasty: Preliminary Genetic Investigation
(CHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS, 2009)
Femoral and acetabular loosening call be attributed different factors, but the Causes and mechanism of early failure are still obscure, The objective of this Study was to investigate the relationship between gene polymorphisms ...
Titanium and zirconia particle-induced pro-inflammatory gene expression in cultured macrophages and osteolysis, inflammatory hyperalgesia and edema in vivo
(Pergamon-elsevier Science LtdOxfordInglaterra, 2014)
Revision after early aseptic failures in primary total knee arthroplasty
(SpringerNew YorkEUA, 2009)
Cemented, cementless or hybrid fixation options in total knee arthroplasty for osteoarthritis and other non-traumatic diseases
(Wiley-Blackwell, 2012-01-01)
BackgroundIt is not clear which fixation of total knee arthroplasty obtains the best clinical, functional and radiographic results in people with osteoarthritis and other non-traumatic diseases, such as rheumatoid ...
10 years results of an uncemented metaphyseal fit modular stem in elderly patients.
(2011)
BACKGROUND: There are concerns with regard to the femoral fixation in cementless total hip arthroplasty in elderly patients. We report a retrospective analysis of clinical and radiological results of uncemented metaphyseal ...
10 years results of an uncemented metaphyseal fit modular stem in elderly patients.
(2011)
BACKGROUND: There are concerns with regard to the femoral fixation in cementless total hip arthroplasty in elderly patients. We report a retrospective analysis of clinical and radiological results of uncemented metaphyseal ...