dc.creatorSIMA, O.
dc.creatorREBEL, H.
dc.creatorHAUNGS, A.
dc.creatorTOMA, G.
dc.creatorMANAILESCU, C.
dc.creatorMORARIU, C.
dc.creatorARTEAGA, J. C.
dc.creatorBEKK, K.
dc.creatorBERTAINA, M.
dc.creatorBLUEMER, J.
dc.creatorBOZDOG, H.
dc.creatorBRANCUS, I. M.
dc.creatorCHIAVASSA, A.
dc.creatorCOSAVELLA, F.
dc.creatorSOUZA, Vitor de
dc.creatorDOLL, P.
dc.creatorENGEL, R.
dc.creatorFINGER, M.
dc.creatorGLASSTETTER, R.
dc.creatorGRUPEN, C.
dc.creatorHECK, D.
dc.creatorHUEGE, T.
dc.creatorKAMPERT, K. -H.
dc.creatorKANG, D.
dc.creatorMATHES, H. -J.
dc.creatorMAYER, H. J.
dc.creatorOEHLSCHLAEGER, J.
dc.creatorROTH, M.
dc.creatorWOCHELE, H.
dc.creatorWOMMER, M.
dc.creatorZABIEROWSKI, J.
dc.date.accessioned2012-10-20T04:21:21Z
dc.date.accessioned2018-07-04T15:43:50Z
dc.date.available2012-10-20T04:21:21Z
dc.date.available2018-07-04T15:43:50Z
dc.date.created2012-10-20T04:21:21Z
dc.date.issued2011
dc.identifierNUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, v.638, n.1, p.147-156, 2011
dc.identifier0168-9002
dc.identifierhttp://producao.usp.br/handle/BDPI/29970
dc.identifier10.1016/j.nima.2011.02.069
dc.identifierhttp://dx.doi.org/10.1016/j.nima.2011.02.069
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1626610
dc.description.abstractThe reconstruction of Extensive Air Showers (EAS) observed by particle detectors at the ground is based on the characteristics of observables like the lateral particle density and the arrival times. The lateral densities, inferred for different EAS components from detector data, are usually parameterised by applying various lateral distribution functions (LDFs). The LDFs are used in turn for evaluating quantities like the total number of particles or the density at particular radial distances. Typical expressions for LDFs anticipate azimuthal symmetry of the density around the shower axis. The deviations of the lateral particle density from this assumption arising from various reasons are smoothed out in the case of compact arrays like KASCADE, but not in the case of arrays like Grande, which only sample a smaller part of the azimuthal variation. KASCADE-Grande, an extension of the former KASCADE experiment, is a multi-component Extensive Air Shower (EAS) experiment located at the Karlsruhe Institute of Technology (Campus North), Germany. The lateral distributions of charged particles are deduced from the basic information provided by the Grande scintillators - the energy deposits - first in the observation plane, then in the intrinsic shower plane. In all steps azimuthal dependences should be taken into account. As the energy deposit in the scintillators is dependent on the angles of incidence of the particles, azimuthal dependences are already involved in the first step: the conversion from the energy deposits to the charged particle density. This is done by using the Lateral Energy Correction Function (LECF) that evaluates the mean energy deposited by a charged particle taking into account the contribution of other particles (e.g. photons) to the energy deposit. By using a very fast procedure for the evaluation of the energy deposited by various particles we prepared realistic LECFs depending on the angle of incidence of the shower and on the radial and azimuthal coordinates of the location of the detector. Mapping the lateral density from the observation plane onto the intrinsic shower plane does not remove the azimuthal dependences arising from geometric and attenuation effects, in particular for inclined showers. Realistic procedures for applying correction factors are developed. Specific examples of the bias due to neglecting the azimuthal asymmetries in the conversion from the energy deposit in the Grande detectors to the lateral density of charged particles in the intrinsic shower plane are given. (C) 2011 Elsevier B.V. All rights reserved.
dc.languageeng
dc.publisherELSEVIER SCIENCE BV
dc.relationNuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment
dc.rightsCopyright ELSEVIER SCIENCE BV
dc.rightsrestrictedAccess
dc.subjectCosmic rays
dc.subjectObservation of Extensive Air Showers
dc.subjectAzimuthal asymmetries of lateral density distributions
dc.titleRestoring the azimuthal symmetry of lateral distributions of charged particles in the range of the KASCADE-Grande experiment
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución