Time domain transient response analysis of three-phase transmission line considering a new skin effect model

dc.creatorMonteiro, José Humberto Araújo, 1981-
dc.date2014
dc.date2014-09-05T00:00:00Z
dc.date2017-04-02T05:20:04Z
dc.date2017-07-13T19:40:05Z
dc.date2017-04-02T05:20:04Z
dc.date2017-07-13T19:40:05Z
dc.date.accessioned2018-03-29T03:48:04Z
dc.date.available2018-03-29T03:48:04Z
dc.identifierMONTEIRO, José Humberto Araújo. Resposta transitória no domínio do tempo de uma linha de transmissão trifásica considerando uma nova implementação do efeito pelicular = Time domain transient response analysis of three-phase transmission line considering a new skin effect model. 2014. 77 f. Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação, Campinas, SP. Disponível em: <http://www.bibliotecadigital.unicamp.br/document/?code=000931336>. Acesso em: 2 abr. 2017.
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/260915
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1336474
dc.descriptionOrientadores: José Pissolato Filho, Eduardo Coelho Marques da Costa
dc.descriptionTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação
dc.descriptionResumo: Este trabalho apresenta o desenvolvimento de um modelo de linha de transmissão trifásica utilizando uma nova implementação do efeito pelicular, além do estudo da resposta transitória obtida a partir do referido modelo quando surtos de manobra são simulados. A metodologia tradicionalmente utilizada para o cálculo da impedância interna de cabos sólidos cilíndricos faz uso das funções de Bessel, o que a torna complexa. A metodologia descrita por Gatous é tão precisa quanto a metodologia que utiliza as funções de Bessel e possui a vantagem de ser mais simples, visto que a solução final é um somatório cuja precisão depende da frequência estudada. O modelo desenvolvido neste trabalho emprega a metodologia de Gatous em uma linha de transmissão trifásica, cujos modos de propagação independentes são obtidos a partir da aplicação da matriz de Clarke. Para validar a metodologia de Gatous, foram calculadas a resistência e a indutância interna de cabos com raios variados em uma ampla faixa de frequências. Os resultados foram comparados aos obtidos a partir da metodologia tradicional. A metodologia de Gatous reproduziu com precisão a variação da impedância interna com a frequência. Para avaliar o funcionamento do modelo de linha de transmissão trifásico no domínio do tempo, um caso base foi estabelecido. Uma linha de transmissão trifásica de 69kV, circuito simples, foi submetida a chaveamentos de carga em duas situações distintas: chaveamento sendo executado no ponto de cruzamento com o zero da tensão e; chaveamento no ponto de 90° da tensão. Os transitórios de tensão e corrente foram obtidos a partir do modelo elaborado e comparados com os resultantes do software de análise de transitórios ATP. Os resultados alcançados reproduzem com fidelidade o comportamento transiente descrito pelo software supracitado
dc.descriptionAbstract: This paper presents the development of a three-phase transmission line model using a new skin effect calculation and its transient response when some switching surges are applied to it. The methodology commonly used to calculate the internal impedance of solid conductors with cylindrical cross sectional area employs Bessel functions, which makes it a hard task to accomplish. Gatous, in his doctoral work, presented a new method to calculate skin effect impedance as accurate as Bessel¿s methodology with advantage of simplicity, whereas that final solution is an algebraic sum whose precision depends of frequency studied. The transmission line model developed in this work utilizes Gatous¿s method for skin effect impedance calculation in a three-phase transmission line, whose independent modes of propagation are obtained from the application of Clarke's matrix. In order to validate the mentioned methodology, internal resistances and inductances of cables with different size radii were calculated for a wide range of frequencies. The results were compared with those obtained through the traditional method, reproducing correctly the variation of the internal impedance with frequency. A base case was established to evaluate the operation of the three-phase transmission line in the time-domain model. A 69kV three-phase transmission line, single circuit, was subjected to switching load in two distinct situations: switching at zero crossing voltage and switching at voltage peak. Voltage and current transients were obtained from the developed model and compared with those derived from transient analysis software ATP. The results faithfully reproduced the transient behavior described by the above software
dc.descriptionDoutorado
dc.descriptionEnergia Eletrica
dc.descriptionDoutor em Engenharia Elétrica
dc.format77 f. : il.
dc.formatapplication/pdf
dc.publisher[s.n.]
dc.subjectEfeito pelicular (Eletricidade)
dc.subjectLinhas elétricas - Transmissão
dc.subjectEnergia elétrica - Transmissão
dc.subjectTransitórios (Eletricidade)
dc.subjectSistemas de potência
dc.subjectSkin effect (Electricity)
dc.subjectElectric lines - Transmission
dc.subjectElectricity - Transmission
dc.subjectTransients (Electricity)
dc.subjectPower systems
dc.titleResposta transitória no domínio do tempo de uma linha de transmissão trifásica considerando uma nova implementação do efeito pelicular = Time domain transient response analysis of three-phase transmission line considering a new skin effect model
dc.titleTime domain transient response analysis of three-phase transmission line considering a new skin effect model
dc.typeTesis


Este ítem pertenece a la siguiente institución