dc.creatorMello L.D.
dc.creatorKubota L.T.
dc.date2002
dc.date2015-06-30T16:45:00Z
dc.date2015-11-26T15:37:24Z
dc.date2015-06-30T16:45:00Z
dc.date2015-11-26T15:37:24Z
dc.date.accessioned2018-03-28T22:45:49Z
dc.date.available2018-03-28T22:45:49Z
dc.identifierFood Chemistry. , v. 77, n. 2, p. 237 - 256, 2002.
dc.identifier10.1016/S0308-8146(02)00104-8
dc.identifierhttp://www.scopus.com/inward/record.url?eid=2-s2.0-0036096757&partnerID=40&md5=6ebe5536bbbca310fda6703da2548bc2
dc.identifierhttp://www.repositorio.unicamp.br/handle/REPOSIP/101906
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/101906
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1263637
dc.descriptionThe food and drink industries need rapid and affordable methods to assure the quality of products and process control, where the use of analytical methods such as high performance liquid chromatography (HPLC) or specific enzymatic methods may be costly or laborious. Application of the biosensor technique in the field of food processing and quality control is promising. Biosensors offer advantages as alternatives to conventional methods due to their inherent specificity, simplicity and quick response. This article presents a review about the potential application of biosensor technology in drink and food industries, its current situation and potential. Some biosensors recently described in the literature are also listed. © 2002 Elsevier Science Ltd. All rights reserved.
dc.description77
dc.description2
dc.description237
dc.description256
dc.descriptionAbad, J.M., Pariente, F., Hernandez, L., Abruña, H.D., Lorenzo, E., Determination of organophosphorus and carbamate pesticides using a piezoelectric biosensor (1998) Analytical Chemistry, 70 (14), pp. 2848-2855
dc.descriptionAlkyilmaz, E., Dinçkaya, E., A new enzyme electrode based on ascorbate oxidase immobilized in gelatin for specific determination of L-ascorbic acid (1999) Talanta, 50 (1), pp. 87-93
dc.descriptionAmárita, F., Fernández, C.R., Alkorta, F., Hybrid biosensors to estimate lactose in milk (1997) Analytica Chimica Acta, 349 (1-3), pp. 153-158
dc.descriptionAndres, R.T., Narayanaswamy, R., Fiber-optic pesticide biosensor based on covalently immobilized acetylcholinesterase and thymol blue (1997) Talanta, 44 (8), pp. 1335-1352
dc.description(1995) Official Methods of Analysis, , Arlington: P.A. Cunniff
dc.descriptionBabacan, S., Pivarnik, P., Letcher, S., Rand, A.G., Evaluation of antibody immobilization methods of piezoelectric biosensor application (2000) Biosensors and Bioelectronics, 15 (11-12), pp. 615-621
dc.descriptionBailey, P.J., Rohrback, B.G., Applications of chemometrics in the food and baverages industry (1994) Food Technology, 48 (4), pp. 69-72
dc.descriptionBartlett, P.N., Booth, S., Caruana, D.J., Kilburn, J.D., Santamaría, C., Modification of glucose oxidase by the covalent attachment of a tetrathiafulvalene derivate (1997) Analytical Chemistry, 69 (4), pp. 734-742
dc.descriptionBassi, A.S., Lee, E., Zhu, J.-X., Carbon paste mediated amperometric thin film biosensors for fructose monitoring in honey (1998) Food Research International, 31 (2), pp. 119-127
dc.descriptionBataillard, P., Calorimetric sensing in bioanalytical chemistry: Principles, applications and trends (1993) Trends in Analytical Chemistry, 12 (10), pp. 387-394
dc.descriptionBaxter, G.A., Ferguson, J.P., O'Connor, M.C., Elliot, C.T., Detection of Streptomycin residues in whole milk using an optical immunobiosensor (2001) Journal of Agricultural and Food Chemistry, 49 (7), pp. 3204-3207
dc.descriptionLuong, J.H.T., Mulchandani, A., Guilbault, G.G., Developments and applications of biosensors (1988) Trends in BioTechnology, 6 (12), pp. 310-316
dc.descriptionMaines, A., Prodromidis, M.I., Karayanni, S.M.T., Karayannis, M.I., Ashworth, D., Vadgama, P., An enzyme electrode for extended linearity citrate measurements based on modified polymeric membranes (2000) Electroanalysis, 12 (14), pp. 1118-1123
dc.descriptionMannino, S., Brenna, O., Buratti, S., Cosio, M.S., Microdialysis-bioreactor for on-line monitoring of glucose in food samples (1997) Electroanalysis, 9 (17), pp. 1337-1340
dc.descriptionMannino, S., Cosio, M.S., Buratti, S., Simultaneous determination of glucose and galactose in dairy products by two parallel amperometric biosensor (1999) Italian Journal of Food Science, 1 (11), pp. 57-65
dc.descriptionMao, L., Yamamoto, K., Amperometric on-line sensor for continuous measurement of hypoxanthine based on osmium-polyvinylpyridine gel polymer and xanthine oxidase bienzyme modified glassy carbon electrode (2000) Analytica Chimica Acta, 415 (1-2), pp. 143-150
dc.descriptionMarconi, E., Baldino, C., Messia, M.C., Cubadda, R., Moscone, D., Palleschi, G., Determination of damaged starch in wheat flour using an electrochemical bienzyme maltose probe (1998) Analytical Letters, 31 (5), pp. 733-749
dc.descriptionMarconi, E., Panfili, G., Messia, M.C., Cubadda, R., Campagnone, D., Palleschi, G., Fast analysis of lysine in food using protein microwave hydrolysis and an electrochemical biosensor (1996) Analytical Letters, 29 (7), pp. 1125-1137
dc.descriptionMatsumoto, K., Asada, W., Murai, R., Simultaneous biosensing of inosine monophosphate and glutamate by use of immobilized enzyme reactors (1998) Analytica Chimica Acta, 858 (2), pp. 127-136
dc.descriptionMedyantseva, E.P., Vertlib, M.G., Budnikov, G.K., Tyshlek, M.P., A new approach to selective detection of 2,4-diclorophenoxyacetic acid with a cholinesterase amperometric biosensor (1998) Applied Biochemistry and Microbiology, 34 (2), pp. 202-205
dc.descriptionMehrvar, M., Bis, C., Scharer, J.M., Mao-Young, M., Luong, J.H.T., Fiber optic biosensors - Trends and advances (2000) Analytical Science, 26 (7), pp. 677-692
dc.descriptionBerchmans, S., Gomathi, H., Rao, G.P., Electrooxidation of alcohols and sugars catalyzed on a nickel-oxide modified glassy-carbon electrode (1995) Journal of ElectroAnalytical Chemistry, 394 (1-2), pp. 267-270
dc.descriptionMellgren, C., Sternesjö, A., Optical immunobiosensor assay for determining enrofloxacin and ciprofloxacin in bovine milk (1998) Journal of AOAC International, 81 (2), pp. 394-397
dc.descriptionMerkoci, A., Braga, S., Fàbregas, E., Alegret, S., A potentiometric biosensor for D-amygdalin based on a consolidated biocomposite membrane (1999) Analytica Chimica Acta, 391 (1), pp. 65-72
dc.descriptionMiertus, S., Katrlík, J., Pizzariello, A., Stred'anský, M., Svitel, J., Svorc, J., Amperometric biosensors based on solid binding matrices applied in food quality monitoring (1998) Biosensors and Bioelectronics, 13 (7-8), pp. 911-923
dc.descriptionMilardovic, S., Grabaric, Z., Grabaric, B.S., Jukic, M., Sensitive amperometric oxalate biosensor for food analysis (2000) Food Technology and BioTechnology, 38 (3), pp. 203-210
dc.descriptionMilardovic, S., Grabaric, Z., Rumenjak, V., Jukic, M., Rapid determination of oxalate by an amperometric oxalate oxidase-based electrode (2000) Electroanalysis, 12 (13), pp. 1051-1058
dc.descriptionMizutani, F., Sato, Y., Hirata, Y., Yabruki, S., High-throughput flow injection analysis of glucose and glutamate in food and biological samples by enzyme/polyon complex-bilayer membrane-based electrodes as the detectors (1998) Biosensors and Bioelectronics, 13 (7-8), pp. 809-815
dc.descriptionMoretto, L.M., Ugo, P., Zanata, M., Guerriero, P., Martin, C.R., Nitrate biosensor based on the ultrathin-film composite membrane concept (1998) Analytical Chemistry, 70 (10), pp. 2163-2166
dc.descriptionMorozova, N.O., Ashin, V.V., Trotsenko, Y.A., Reshetilov, A.N., Amperometric detection of aliphatic alcohols by using immobilized alcohol oxidase from the methylotrophic Yeast Pichia Methanolica (1999) Applied Biochemistry and Microbiology, 35 (5), pp. 537-541
dc.descriptionMosbach, K., Thermal biosensors (1995) Biosensors and Bioelectronics, 6 (3), pp. 179-182
dc.descriptionMoscone, D., Bernardo, R.A., Marconi, E., Amine, A., Palleschi, G., Rapid determination of lactulose in milk by microdialysis and biosensors (1999) Analyst, 124 (3), pp. 325-329
dc.descriptionBerchmans, S., Gomathi, H., Rao, G.P., Enzymeless approach for the determination of some biologically important species (1998) Sensors and Actuators B, 50 (2), pp. 156-163
dc.descriptionMullet, W., Lai, E.P.C., Yeung, J.M., Immunoassay of fumonisins by a surface plasmon resonance biosensor (1998) Analytical BioChemistry, 258 (2), pp. 161-167
dc.descriptionMullor, S.G., Cabezudo, M.S., Ordieres, A.J.M., Ruiz, B.L., Alcohol biosensor based on alcohol dehydrogenase and meldola blue immobilized into a carbon paste electrode (1996) Talanta, 43 (5), pp. 779-784
dc.descriptionNice, E.C., Catimel, B., Instrumental biosensors: New perpectives for the analysis of biomolecular interactions (1999) Bioessays, 21 (4), pp. 339-352
dc.descriptionNiculescu, M., Frébort, I., Pec, P., Galuszka, P., Mattiasson, B., Csöregi, E., Amine oxidase based amperometric biosensors for histamine detection (2000) Electroanalysis, 12 (5), pp. 369-375
dc.descriptionNiculescu, M., Nistor, C., Frébort, I., Pec, P., Mattiasson, B., Csöregi, E., Redox hydrogel-based amperometric bienzyme electrodes for fish freshness monitoring (2000) Analytical Chemistry, 72 (7), pp. 1591-1597
dc.descriptionNoguer, T., Marty, J.-L., Reagentless sensors for acetaldehyde (1997) Analytical Letters, 30 (6), pp. 1069-1080
dc.descriptionNunes, G.S., Skládal, P., Yamanaka, H., Barceló, D., Determination of carbamates residues in crop samples by cholinesterase-based biosensors and chromatographic techniques (1998) Analytica Chimica Acta, 362 (1), pp. 59-68
dc.descriptionNunes, G.S., Barceló, D., Grabaric, B.S., Diaz-Cruz, J.M., Ribeiro, M.L., Evaluation of a highly sensitive amperometric biosensor with low cholinesterase charge immobilized on a chemically modified carbon paste electrode for trace determination of carbamates in fruit, vegetable and water samples (1999) Analytica Chimica Acta, 399 (1-2), pp. 37-49
dc.descriptionOhashi, E., Karube, I., Sensors for the food industry (1993) Food Control, 4 (4), pp. 183-188
dc.descriptionOlschewski, H., Erlenkötter, A., Zaborosch, C., Chemnitius, G.C., Screen-printed enzyme sensors for L-lysine determination (2000) Enzymes and Microbial Technology, 26 (7), pp. 537-543
dc.descriptionBergstrom, C., Sternesjo, A., Bjurling, P., Lofar, S., Design and use of a general capturing surface in optical biosensor analysis of sulphamethazine in milk (1999) Food and Agricultural and Immunology, 11 (4), pp. 329-338
dc.descriptionO'Sullivan, C.K., Vaughan, R., Guilbault, G.G., Piezoelectric immunosensors-theory and applications (1999) Analytical Letters, 32 (12), pp. 2353-2377
dc.descriptionPalchetti, I., Cagnini, A., Del Carlo, M., Coppi, C., Mascini, M., Turner, A.P.F., Determination of anticholinesterase pesticides in real samples using a disposable biosensor (1997) Analytica Chimica Acta, 337 (3), pp. 315-321
dc.descriptionPalmisano, F., Rizzi, R., Centonze, D., Zambonin, P.G., Simultaneous monitoring of glucose and lactose by an interference and cross-talk free dual electrode amperometric biosensor based on electropolymerized thin films (2000) Biosensors and Bioelectronics, 15 (9-10), pp. 531-539
dc.descriptionPanfili, G., Manzi, P., Campagnone, D., Scarciglia, L., Palleschi, G., Rapid assay of choline in foods using a microwave hydrolysis and a choline biosensor (2000) Journal of Agricultural and Food Chemistry, 48 (8), pp. 3403-3407
dc.descriptionParedes, P.A., Parellada, J., Fernández, V.M., Katakis, I., Domínguez, E., Amperometric mediated carbon paste biosensor based on D-fructose dehydrogenase for the determination of fructose in food analysis (1997) Biosensors and Bioelectronics, 12 (12), pp. 1233-1243
dc.descriptionPark, I.-S., Cho, Y.-J., Kim, N., Characterization and meat freshness application of a serial three-enzyme reactor system measuring ATP-degradative compounds (2000) Analytica Chimica Acta, 415 (1-2), pp. 75-81
dc.descriptionPei, J., Li, X.-Y., Xanthine and hypoxanthine sensors based on xanthine oxidase immobilized on a CuPtCl6 chemically modified electrode and liquid chromatography electrochemical detection (2000) Analytica Chimica Acta, 414 (1-2), pp. 205-213
dc.descriptionPerez, E.F., Neto, G.O., Kubota, L.T., Bienzymatic amperometric biosensor for oxalate (2001) Sensors and Actuators B, 72 (1), pp. 80-85
dc.descriptionPhadke, R.S., Biosensors and enzyme immobilized electrodes (1992) Biosystems, 27 (4), pp. 203-206
dc.descriptionPita, M.T.P., Reviejo, A.J., Villena, F.J.M., Pingarrón, J.M., Amperometric selective biosensing of dimethyl-and diethyldithiocarbamates based on inhibition processes in a medium of reversed micelles (1997) Analytica Chimica Acta, 340 (1-3), pp. 89-97
dc.descriptionBilitewski, U., Can affinity sensors be used to detect food contaminants (2000) Analytical Chemistry, 72 (1), pp. 693A-701A
dc.descriptionProdromidis, M.I., Karayanni, S.M.T., Karayannis, M.I., Vadgama, P.M., Bioelectrochemical determination of citric acid in real samples using a fully automated flow injection manifold (1997) Analyst, 122 (10), pp. 1101-1106
dc.descriptionQiong, C., Tuzhi, P., Liju, Y., Silk fibroin/cellulose acetate membrane electrodes incorporing xanthine oxidase for the determination of fish freshness (1998) Analytica Chimica Acta, 369 (3), pp. 245-251
dc.descriptionRamanathan, K., Jonsson, B., Danielsson, B., Sol-gel based thermal biosensor for glucose (2001) Analytica Chimica Acta, 427 (1), pp. 1-10
dc.descriptionRamanathan, K., Rank, M., Svitel, J., Dzgoev, A., Danielsson, B., The developments and application of thermal biosensors for bioprocess monitoring (1999) Trends in BioTechnology, 17 (12), pp. 499-505
dc.descriptionRamsay, G., (1998) Commercial biosensors, , New York: John Wiley
dc.descriptionRasooly, A., Surface plasmon resonance analysis of Staphylococcal enterotoxin B in food (2001) Journal of Food Protection, 64 (1), pp. 37-43
dc.descriptionRasooly, A., Rasooly, L., Real time biosensor analysis of Staphylococcal enterotoxin A in food (1999) International Journal of Food Microbiology, 49 (3), pp. 119-127
dc.descriptionRishpon, J., Ivnitski, D., An amperometric enzyme-channeling immunosensor (1997) Biosensors and Bioelectronics, 12 (3), pp. 195-204
dc.descriptionRomani, A., Minunni, M., Mulinacci, N., Pinelli, P., Vincieri, F.F., Del Carlo, M., Mascini, M., Comparison among differential pulse voltammetry amperometric biosensor and HPLC/DAD analysis for polyphenols determination (2000) Journal of Agricultural and Food Chemistry, 48 (4), pp. 1197-1203
dc.descriptionSarkar, P., Tothiel, I.E., Setford, S.J., Turner, A.P.F., Screen-printed amperometric biosensors for the rapid measurement of L and D-amino acids (1999) Analyst, 124 (6), pp. 865-870
dc.descriptionBizet, K., Gabrielli, C., Perrot, H., Biosensors based on piezoelectric transducers (1999) Analusis, 27 (7), pp. 609-616
dc.descriptionScheper, T., Hitzmann, B., Stark, E., Ulber, R., Faurie, R., Sosnitza, P., Reardon, K.F., Bioanalytics: Detailed insight into bioprocesses (1999) Analytica Chimica Acta, 400, pp. 121-134
dc.descriptionSeitz, W.R., Chemical sensors based on immobilized indicators and fiber optics (1988) CRC Critical Reviews in Analytical Chemistry, 19, pp. 135-173
dc.descriptionSekine, Y., Hall, E.A.H., A lactulose sensor based on coupled enzyme reactions with a ring electrode fabricated from tetrathiafulvalen-tetracyanoquinodimatane (1998) Biosensors and Bioelectronics, 13 (9), pp. 995-1005
dc.descriptionShin, S.J., Yamanaka, H., Endo, H., Watanabe, E., Development of ornithine biosensor and application to estimation of prawn freshness (1998) Analytica Chimica Acta, 364 (1-3), pp. 159-164
dc.descriptionSitumorang, M., Lubbert, D.B., Gooding, J.J., A sulfite biosensor fabricated using electrodeposited polytyramine: Application to wine analysis (1999) Analyst, 124 (12), pp. 1775-1779
dc.descriptionSouteyrand, E., DNA Chips: From elaboration to application (1999) Analusis, 27 (7), pp. 639-646
dc.descriptionStarodub, N.F., Dzantiev, B.B., Starodub, V.M., Zherdev, A.V., Immunosensor for the determination of the herbicide simazine based on an ion-selective-field-effect transistor (2000) Analytica Chimica Acta, 424 (1), pp. 37-43
dc.descriptionSteegborn, C., Skládal, P., Construction and characterization of the direct piezoelectric immunosensor for atrazine operating in solution (1997) Biosensors and Bioelectronics, 12 (1), pp. 19-27
dc.descriptionStefan, R.I., Van Staden, J.F., Aboul-Enein, H.Y., Electrochemical sensor arrays (1999) CRC Critical Reviews in Analytical Chemistry, 29 (2), pp. 133-153
dc.descriptionSternesjo, A., Mellgren, C., Bjorck, L., Determination of sulfamethazine residues in milk by a surface-plasmon resonance-based biosensor assay (1995) Analytical BioChemistry, 226 (1), pp. 175-181
dc.descriptionBlum, L.J., Gautier, S.M., Coulet, P.R., Luminescence fiber optic biosensor (1988) Analytical Letters, 21 (5), pp. 717-726
dc.descriptionStred'anský, M., Pizzariello, A., Stredonska, S., Miertus, S., Determination of D-fructose in foodstuffs by an improved amperometric biosensor based on a solid binding matrix (1999) Analytical Communications, 36 (2), pp. 57-61
dc.descriptionSu, X., Low, S., Kwang, J., Chew, V.H.T., Li, S.F.Y., Piezoelectric quartz crystal based veterinary diagnosis for Salmonella enteritidis infection in chicken and egg (2001) Sensors and Actuators B, 75 (1-2), pp. 29-35
dc.descriptionSvorc, J., Miertus, S., Katrlík, J., Stred'anský, M., Composite transducers for amperometric biosensors. The glucose sensor (1997) Analytical Chemistry, 69 (11), pp. 2086-2090
dc.descriptionTaylor, R.F., Marenchic, I.G., Spencer, R.H., Antibody and receptor based biosensors for detection and process control (1991) Analytica Chimica Acta, 249 (1), pp. 67-70
dc.descriptionThévenot, D.R., Toth, K., Durst, R.A., Wilson, G.S., Electrochemical biosensors: Recommended definitions and classification (2001) Biosensors and Bioelectronics, 16 (1-2), pp. 121-131
dc.descriptionTobalina, F., Pariente, F., Hernández, L., Abruña, H.D., Lorenzo, E., Integrated ethanol biosensors based on carbon paste electrodes modified with [Re(phen-dione)(CO)3Cl ] and [Fe(phen-dione)3 PF6)2] (1999) Analytica Chimica Acta, 395 (1-2), pp. 17-26
dc.descriptionTombelli, S., Mascini, M., Electrochemical biosensors for biogenic amines: A comparison between different approaches (1998) Analytica Chimica Acta, 358 (3), pp. 277-284
dc.descriptionTothill, I.E., Biosensors developments and potential applications in the agricultural diagnosis sector (2001) Computers and Electronics in Agriculture, 30 (1-3), pp. 205-218
dc.descriptionUpdike, S.J., Hicks, G.P., Enzyme electrode (1967) Nature, 214 (5092), p. 986
dc.descriptionVega, F.A., Núñez, C.G., Weigel, B., Hitzmann, B., Ricci, J.C.D., On line monitoring of galactoside conjugates and glycerol by flow injection analysis (1998) Analytica Chimica Acta, 373 (1), pp. 57-62
dc.descriptionBlum, L.J., Gautier, S.M., Coulet, P.R., Fiber optic biosensors with immobilized bioluminescence enzymes (1991) Journal of Material Science: Materials in Medicine, 2 (4), pp. 202-204
dc.descriptionVolotovsky, V., Kim, N., Determination of glucose, ascorbic acid and citric acids by two-ISFET multienzyme sensor (1998) Sensors and Actuators B, 49 (3), pp.
dc.descriptionBoer, E., Beumer, R.R., Methodology for detection and typing of foodborne microorganisms (1999) International Journal of Food Microbiology, 50 (1-2), pp. 119-130
dc.descriptionBoujtita, M., Hart, J.P., Pittson, R., Development of a disposable ethanol biosensor based on a chemically modified screen-printed electrode coated with alcohol oxidase for the analysis of beer (2000) Biosensors and Bioelectronics, 15 (5-6), pp. 257-263
dc.descriptionBoujtita, M., Murr, N.El., Ferrocene-mediated carbon paste electrode modified with D-fructose dehydrogenase for batch mode measurement of D-fructose (2000) Applied BioChemistry and BioTechnology, 89 (1), pp. 55-66
dc.descriptionBourgeois, W., Burgess, J.E., Stultz, R.M., On-line monitoring of wastewater quality: A review (2001) Journal of Chemistry Technology and BioTechnology, 76 (4), pp. 337-348
dc.descriptionBouvrette, P., Male, K.B., Luong, J.H.T., Gibbs, B.F., Amperometric biosensor for diamine using oxidase purified from porcine kidney (1997) Enzyme & Microbial Technology, 20 (1), pp. 32-38
dc.descriptionBrooks, J.L., Mirhabibollahi, B., Kroll, R.G., Experimental enzyme-linked amperometric immunosensors for the detection of Salmonella in foods (1992) Journal of Applied Bacteriology, 73 (3), pp. 189-196
dc.descriptionBuhlmann, P., Pretsch, E., Bakker, E., Carrier-based ion-selective electrodes and bulk optodes (1998) 2. Ionophores for potentiometric and optical sensors. Chemistry Reviews, 98 (4), pp. 1593-1687
dc.descriptionCampagnone, D., Esti, M., Messia, M.C., Peluso, E., Palleschi, G., Development of a biosensor for monitoring of glycerol during alcoholic fermentation (1998) Biosensors and Bioelectronics, 13 (7-8), pp. 875-880
dc.descriptionCampagnone, D., O'Sullivan, D., Guilbault, G.G., Amperometric bienzymatic sensor for aspartame (1997) Analyst, 122 (5), pp. 487-490
dc.descriptionCampanella, L., De Luca, S., Sammartino, M.P., Tomassetti, M., A new organic phase enzyme electrode for the analysis of orgaphosphorus pesticides and carbamates (1999) Analytica Chimica Acta, 385 (1-3), pp. 59-71
dc.descriptionCampanella, L., Favero, G., Pastorino, M., Tomassetti, M., Monitoring the rancification process in olive oils using a biosensor operating in organic solvents (1999) Biosensors and Bioelectronics, 14 (2), pp. 179-186
dc.descriptionCapannesi, C., Palchetti, I., Mascini, M., Parenti, A., Electrochemcial sensor and biosensor for polyphenols detection in olive oils (2000) Food Chemistry, 71 (4), pp. 553-562
dc.descriptionCarter, R.M., Jacobs, M.B., Lubrano, G.J., Guilbault, G.G., Rapid detection of aflatoxin B1 with immunochemical optodes (1997) Analytical Letters, 30 (8), pp. 1465-1482
dc.descriptionCasella, I.G., Cataldi, T.R.I., Salvi, A.M., Desimoni, E., Electrocatalytic oxidation and liquid-chromatographic detection of aliphatic-alcohols at a nickel-based glassy-carbon modified electrode (1993) Analytical Chemistry, 65 (21), pp. 3143-3150
dc.descriptionCasella, I.G., Desimoni, E., Salvi, A.M., Chemically modified electrode for the detection of carbohydrates (1991) Analytica Chimica Acta, 243 (1), pp. 61-63
dc.descriptionCaselunghe, M.B., Lindeberg, J., Biosensor-based determination of folic acid in fortified food (2000) Food Chemistry, 70 (4), pp. 523-532
dc.descriptionCastañón, M.J.L., Ordieres, A.J.M., Blanco, P.T., A bienzyme-poly-(o-phenylenediamine)-modified carbon paste electrode for the amperometric detection of L-lactate (1997) Analytica Chimica Acta, 346 (2), pp. 165-174
dc.descriptionCentonze, D., Zambonin, C.G., Palmisano, F., Determination of glucose in nonalcoholic beverages by a biosensor coupled with microdialysis fiber samplers (1997) Journal of AOAC International, 80 (4), pp. 829-833
dc.descriptionChe, Y.H., Li, Y., Slavik, M., Paul, D., Rapid detection of Salmonella typhimurium in chicken carcass wash water using an immunoelectrochemical method (2000) Journal of Food Protection, 63 (8), pp. 1043-1048
dc.descriptionCosnier, S., Gondran, C., Watelet, J.C., De Giovani, W., Furriel, R.P.M., Leone, F.A., A bienzyme electrode (alkaline phosphatase-polyphenol oxidase) for the amperometric determination of phosphate (1998) Analytical Chemistry, 70 (18), pp. 3952-3956
dc.descriptionCurulli, A., Kelly, S., O'Sullivan, C.O., Guilbault, G.G., Palleschi, G., A new interference-free lysine biosensor using a non-conducting polymer film (1998) Biosensors and Bioelectronics, 13 (12), pp. 1245-1250
dc.descriptionDall'Orto, V.C., Danilowicz, C., Rezzano, I., Del Carlo, M., Mascini, M., Comparison between three amperometric sensors for phenol determination in olive oil samples (1999) Analytical Letters, 32 (10), pp. 1981-1990
dc.descriptionDavis, J., Vaughan, D.H., Cardosi, M.F., Elements of biosensors construction (1995) Enzyme and Microbial Technology, 17 (12), pp. 1030-1035
dc.descriptionDel Cerro, M.A., Cayuela, G., Reviejo, A.J., Pingarrón, J.M., Wang, J., Graphite-teflon-peroxidase composite electrodes. Application to the direct determination of glucose in musts and wines (1997) Electroanalysis, 9 (14), pp. 1113-1119
dc.descriptionDeMarco, D.R., Saaski, E.W., McCrae, D.A., Lim, D.V., Rapid detection of Escherichia coli O157:H7 in ground beef using a fiber-optic biosensor (1999) Journal of Food Protection, 62 (7), pp. 711-716
dc.descriptionDeng, Q., Dong, S., Amperometric biosensor for tyrosinase inhibitors in a pure organic phase (1996) Analyst, 121 (12), pp. 1979-1982
dc.descriptionDeshpande, S.S., Rocco, R.M., Biosensors and their potential use in food quality control (1994) Food Technology, 48 (6), pp. 146-150
dc.descriptionDinçkaya, E., Akyilmaz, E., Akgöl, S., Önal, S.T., Zihnioglu, F., Telefoncu, A., A novel catechol oxidase enzyme electrode for the specific determination of catechol (1998) Bioscience Biotechnology and Biochemistry, 62 (11), pp. 2098-2100
dc.descriptionDong R.-An, Tsai, H.-C., Immobilization and characterization of sol-gel encapsulated acetylcholinesterase fiber-optic biosensor (2001) Analytica Chimica Acta, 434 (2), pp. 239-246
dc.descriptionDraisci, R., Volpe, G., Lucentini, L., Cecília, A., Frederico, R., Palleschi, G., Determination of biogenic amines with an electrochemical biosensor and its to salted anchovies (1998) Food Chemistry, 62 (2), pp. 225-232
dc.descriptionDremel, B.A.A., Schaffar, B.P.H., Schmid, R.D., Determination of glucose in wine and fruit juice based on a fiber-optic glucose and flow-injection analysis (1989) Analytica Chimica Acta, 225 (2), pp. 293-301
dc.descriptionEggins, B.R., Hickey, C., Toft, S.A., Zhou, D.Min., Determination of flavonols in beers with tissue biosensors (1997) Analytica Chimica Acta, 347 (3), pp. 281-288
dc.descriptionEsti, M., Volpe, G., Massigan, L., Campagnone, D., La Notte, E., Palleschi, G., Determination of amines in fresh and modified atmosphere packaged fruits using electrochemical biosensors (1998) Journal of Agricultural and Food Chemistry, 46 (10), pp. 4233-4237
dc.descriptionFeng, P., Commercial assay systems for detecting foodborne Salmonella: A review (1992) Journal of Food Protection, 55 (11), pp. 927-934
dc.descriptionFitzpatrick, J., Fanning, L., Hearty, S., Leonard, P., Manning, B.M., Quinn, J.Q., O'Kennedy, R., Applications and recent developments in the use of antibodies for analysis (2000) Analytical Letters, 33 (13), pp. 2563-2609
dc.descriptionGajovic, N., Warsinke, A., Scheller, F.W., Comparison of two enzymes sequences for a novel L-malate biosensor (1997) Journal of Chemistry Technology and BioTechnology, 68, pp. 31-36
dc.descriptionGajovic, N., Warsinke, A., Scheller, F.W., A bienzyme electrode for L-malate based on a novel and general design (1998) Journal of BioTechnology, 61 (2), pp. 129-133
dc.descriptionGarcia, C.A.B., Neto, G.O., Kubota, L.T., New fructose biosensors utilizing a polypyrrole film and D-fructose 5-dehydrogenase immobilized by different processes (1998) Analytica Chimica Acta, 374 (2-3), pp. 201-208
dc.descriptionGaudin, V., Maris, P., Development of a biosensor-based immunoassay for screening of chloramphenicol residues in milk (2001) Food and Agricultural and Immunology, 13 (2), pp. 77-86
dc.descriptionGavalas, V.G., Fouskaki, M.G., Chaniotakis, N.A., Novel pre-oxiding cell for elimination of electroactive interferents during biosensor analysis. Application to glucose determination in real samples (2000) Analytical Letters, 33 (12), pp. 2391-2405
dc.descriptionGe, F., Zhang, X.-En., Zhang, Z.-P., Zhang, X.-M., Potassium ferricyanide mediated disposable biosensor for determination of maltose and glucose (1998) Analytical Letters, 31 (3), pp. 383-394
dc.descriptionGhindilis, A.L., Atanasov, P., Wilkins, E., Enzyme-catalyzed direct electron transfer: Fundamentals and analytical applications (1997) Electroanalysis, 9 (9), pp. 661-674
dc.descriptionGibson, D.M., Coombs, P., Pimbley, D.W., Automated conductance method for the detection of Salmonella in foods: Collaborative study (1992) Journal of AOAC International, 75 (2), pp. 293-297
dc.descriptionGibson, T.D., Biosensors: The stability problem (1999) Analusis, 27 (7), pp. 630-638
dc.descriptionGooding, J.J., Erokhin, P., Losic, D., Yang, W.R., Policarpo, V., Liu, J.Q., Ho, F.M., Shapter, J.G., Parameters important in fabricating enzyme electrode using self-assembled monolayers of alkanethiols (2001) Analytical Science, 17 (1), pp. 3-9
dc.descriptionGrate, J.W., Rosepehrsson, S.L., Venezky, D.L., Klusty, M., Wohltjen, H., Smart sensor system for trace organophosphorus and organosulfur vapor detection employing a temperature-controlled array of surface-acoustic wave sensors, automated sample preconcentration and pattern-recognition (1993) Analytical Chemistry, 64 (14), pp. 1868-1881
dc.descriptionGuilbault, G.G., (1970) Enzymatic methods of analysis, , New York: Pergamon
dc.descriptionHaasnoot, W., Verheijen, R., A direct (non-competitive) immunoassay for gentamicin residues with an optical biosensor (2001) Food and Agricultural and Immunology, 13 (2), pp. 131-134
dc.descriptionHabermüller, K., Mosbach, M., Schuhmann, W., Electron-transfer mechanisms in amperometric biosensors (2000) Fresenius Journal of Analytical Chemistry, 366 (6-7), pp. 560-568
dc.descriptionHamid, I.A., Ivnitski, D., Atanasov, P., Wilkins, E., Fast amperometric assay for E. coli O157:H7 using partially immersed immunoelectrodes (1998) Electroanalysis, 10 (11), pp. 758-763
dc.descriptionHamid, I.A., Ivnitski, D., Atanasov, P., Wilkins, E., Highly sensitive flow-injection immunoassay system for rapid detection of bacteria (1999) Analytica Chimica Acta, 399 (1-2), pp. 99-108
dc.descriptionHarteveld, J.L.N., Nieuwenhuizen, M.S., Wils, E.R.J., Detection of Staphylococcal Enterotoxin B employing a piezoelectric crystal immunosensor (1997) Biosensors and Bioelectronics, 12 (7), pp. 661-667
dc.descriptionHibi, T., Senda, M., Enzymatic assay of histamine by amperometric detection of H2O2 with a peroxidase-based sensor (2000) Bioscience Biotechnology Biochemistry, 64 (9), pp. 1963-1966
dc.descriptionHomola, J., Yee, S.S., Gauglitz, G., Surface plasmon resonance sensors: Review (1999) Sensors and Actuators B, 54 (1-2), pp. 3-15
dc.descriptionHoracek, J., Garrett, S.D., Skládal, P., Morgan, M.R.A., Characterization of the interactions between immobilized parathion and the corresponding recombinant scFv antibody using a piezoelectric biosensor (1998) Food and Agricultural and Immunology, 10 (4), pp. 363-374
dc.descriptionHu, S., Liu, C.-C., Amperometric sensor for fish freshness based on immobilized multi-enzyme modified electrode (1997) Electroanalysis, 9 (16), pp. 1229-1233
dc.descriptionImabayashi, S., Kong, Y.T., Watanabe, M., Amperometric biosensor for polyphenols based on Horseradish peroxidase immobilized on gold electrodes (2001) Electroanalysis, 13 (5), pp. 408-412
dc.descriptionIndyk, H.E., Evans, E.A., Caselunghe, M.C.B., Persson, B.S., Finglas, P.M., Woollard, D.C., Filonzi, E.L., Determination of biotin and folate in infant formula and milk by optical biosensor-based immunoassay (2000) Journal of AOAC International, 83 (5), pp. 1141-1148
dc.descriptionIvanov, A.N., Evtugyn, G.A., Gyurcsányi, R.E., Tóth, K., Budnikov, H.C., Comparative investigation of electrochemical cholinesterase biosensors for pesticide determination (2000) Analytica Chimica Acta, 404 (1), pp. 55-65
dc.descriptionIvnitski, D., Hamid, I.A., Atanasov, P., Wilkins, E., Biosensors for detection of pathogenic bacteria (1999) Biosensors and Bioelectronics, 14 (7), pp. 599-624
dc.descriptionKarube, I., Suzuki, M., Microbiosensors for food analysis (1992) ACS Symposium Series, 511, pp. 10-25
dc.descriptionKatrlík, J., Pizzarielo, A., Mastihuba, V., Svorc, J., Stred'anský, X., Miertus, S., Biosensors for L-malate and L-lactate based on solid binding matrix (1999) Analytica Chimica Acta, 379 (1-2), pp. 193-200
dc.descriptionKatrlík, J., Svorc, J., Stred'anský, M., Miertus, S., Composite alcohol biosensors based on solid binding matrix (1998) Biosensors and Bioelectronics, 13 (2), pp. 183-191
dc.descriptionKelly, S.C., O'Connell, P.J., O'Sullivan, C.K., Guilbault, G.G., Development of an interferent free amperometric biosensor for determination of L-lysine in food (2000) Analytica Chimica Acta, 412 (1-2), pp. 111-119
dc.descriptionKilinc, E., Erdem, A., Gokgunnec, L., Dalbasti, T., Karaoglan, M., Ozsoz, M., Buttermilk based cobalt phthalocyanine dispersed ferricyanide mediated amperometric biosensor for the determination of xanthine (1998) Electroanalysis, 10 (4), pp. 273-275
dc.descriptionKillard, A.J., Smyth, M.R., Separation-free electrochemical immunosensor strategies (2000) Analytical Letters, 33 (8), pp. 1451-1465
dc.descriptionKinnear, K.T., Monbouquette, H.G., An amperometric fructose biosensor based on fructose dehydrogenase immobilized in a membrane memetic layer on gold (1997) Analytical Chemistry, 69 (9), pp. 1771-1775
dc.descriptionKiranas, E.R., Karayannis, M.I., Karayanni, S.M.T., An enzymatic method for the determination of ATP and glycerol with an automated FIA system (1997) Analytical Letters, 30 (3), pp. 537-552
dc.descriptionKoncki, R., Glab, S., Dzimulska, J., Palchetti, I., Mascini, M., Disposable strip potentiometric electrodes with solvent-polymeric ion-selective membrane fabricated using screen-printing technology (1999) Analytica Chimica Acta, 385 (1-3), pp. 451-459
dc.descriptionKorpan, Y.I., Gonchar, M.V., Sibirny, A.A., Martelet, C., El'skaya, A.V., Gibson, T.D., Soldatkin, A.P., Development a highly selective and stable potentiometric sensors for formaldehyde determination (2000) Biosensors and Bioelectronics, 15 (1-2), pp. 77-83
dc.descriptionKotsira, V.P., Clonis, Y.D., Colorimetric assay for lecithin using two co-immobilized enzymes and an indicator dye conjugate (1998) Journal of Agricultural and Food Chemistry, 46 (8), pp. 3389-3394
dc.descriptionKrull, U.J., Biosensors for chemical analysis (1990) Chemtech, 20 (6), pp. 372-377
dc.descriptionKwog, A.W.K., Gründig, B., Hu, J., Renneberg, R., Comparative study of hydrogel-immobilized L-glutamate oxidases for a novel thick-film biosensor and its application in food samples (2000) BioTechnology Letters, 22 (4), pp. 267-272
dc.descriptionKwun, Un-S., Lee, H.-S., Kim, M., Potentiometric determination of L-malate using ion-selective electrode in flow injection analysis system (1999) Journal of Food Science and Nutrition, 4 (1), pp. 79-83
dc.descriptionLatif, M.S.A., Guilbault, G.G., Fiber optic sensor for the determination of glucose using micellar enhanced chemiluminescence of the peroxyoxalate reaction (1988) Analytical Chemistry, 60 (15), pp. 2671-2679
dc.descriptionLeca, B., Marty, J.-L., Reusable ethanol sensor based on a NAD+-dependent dehydrogenase without coenzyme addition (1998) Analytica Chimica Acta, 340 (1-3), pp. 143-148
dc.descriptionLee, Y.C., Huh, M.H., Development of a biosensor with immobilized L-amino acid oxidase for determination of L-amino acids (1999) Journal of Food BioChemistry, 23 (2), pp. 173-185
dc.descriptionLi, Y.-G., Zhou, Y.-X., Feng, J.-L., Jiang, Z.-H., Ma, L.-R., Immobilization of enzyme on screen-printed electrode by exposure to glutaraldehyde vapour for the construction of amperometric acetylcholinesterase electrodes (1999) Analytica Chimica Acta, 382 (3), pp. 277-282
dc.descriptionLiu, H., Li, H., Ying, T., Sun, K., Qin, Y., Qi, D., Amperometric biosensor sensitive to glucose and lactose based on co-immobilization of ferrocene, glucose oxidase, β-galactosidase and mutarotase in β-cyclodextrin polymer (1998) Analytica Chimica Acta, 358 (2), pp. 137-144
dc.descriptionLiu, S., Xu, C., Luo, J., Luo, J., Cui, D., Biosensor for detection of hypoxanthine based on xanthine oxidase immobilized on chemically modified carbon paste electrode (2000) Analytica Chimica Acta, 412 (1-2), pp. 55-61
dc.descriptionLuong, J.H.T., Brown, R.S., Male, K.B., Cattaneo, M., Zhao, S.S., Enzyme reactions in the presence of cyclodextrins: Biosensors and enzyme assays (1995) Trends in BioTechnology, 13 (11), pp. 457-463
dc.descriptionLuong, J.H.T., Groom, C.A., Male, K.B., Potential role of biosensors in the food and drink industries (1991) Biosensors and Bioelectronics, 6 (7), pp. 547-554
dc.relationFood Chemistry
dc.rightsfechado
dc.sourceScopus
dc.titleReview Of The Use Of Biosensors As Analytical Tools In The Food And Drink Industries
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución