Artículos de revistas
Electromechanical analysis of a piezoresistive pressure microsensor for low-pressure biomedical applications
Electromechanical analysis of a piezoresistive pressure microsensor for low-pressure biomedical applications
Autor
Herrera-May, A. L.
Soto-Cruz, B. S.
López-Huerta, F.
Aguilera Cortés, L. A.
Institución
Resumen
El análisis electromecánico de un microsensor de presión piezoresistivo con un diafragma de sección cuadrada para aplicaciones biomédicas de baja presión es presentado. Este análisis es desarrollado mediante un nuevo modelo polinomial y un modelo con el método elemento finito (FEM). Un microsensor con un diafragma de 1000 μm de longitud y tres diferentes espesores (10, 15 y 20 μm) es estudiado. La respuesta eléctrica de éste microsensor es obtenida mediante un puente de Wheatstone con cuatro piezoresistores tipo p localizados sobre la superficie del diafragma. El diafragma con 10 μm de espesor presenta una deflexión máxima de 3.74 μm utilizando el modelo polinomial, el cual tiene una diferencia relativa de 5.14 and 0.92% con respecto al modelo de Timoshenko y al modelo FEM, respectivamente. La máxima sensibilidad y esfuerzo normal calculado con el modelo polinomial son 1.64 mV/V/kPa and 102.1 MPa, respectivamente. Los resultados del modelo polinomial concuerdan bien con el modelo de Timoshenko y el modelo FEM para pequeñas deflexiones. Además, el modelo polinomial puede ser utilizado fácilmente para predecir la deflexión, esfuerzo normal, respuesta eléctrica y sensibilidad de un microsensor de presión piezoresistivo con un diafragma de sección cuadrada sujeto a pequeñas deflexiones. The electromechanical analysis of a piezoresistive pressure microsensor with a square-shaped diaphragm for low-pressure biomedical applications is presented. This analysis is developed through a novel polynomial model and a finite element method (FEM) model. A microsensor with a diaphragm 1000 μm length and with three different thicknesses (10, 15, and 20 μm) is studied. The electric response of this microsensor is obtained with a Wheatstone bridge of four p-type piezoresistors located on the diaphragm surface. The diaphragm that is 10 μm thickexhibits a maximum deflection of 3.74 μm using the polynomial model, which has a relative difference of 5.14 and 0.92% with respect to the Timoshenko model and the FEM model, respectively. The maximum sensitivity and normal stress calculated using the polynomial model are 1.64 mV/V/kPa and 102.1 MPa, respectively. The results of the polynomial model agree well with the Timoshenko model and FEM model for small deflections. In addition, the polynomial model can be easily used to predict the deflection, normal stress, electric response and sensitivity of a piezoresistive pressure microsensor with a square-shaped diaphragm under small deflections.
Ítems relacionados
Mostrando ítems relacionados por Título, autor o materia.
-
Simultaneous inter-arm and inter-leg systolic blood pressure differences to diagnose peripheral artery disease: a diagnostic accuracy study
Herráiz-Adillo Á.; Soriano-Cano A.; Martínez-Hortelano J.A.; Garrido-Miguel M.; Mariana-Herráiz J.Á.; Martínez-Vizcaíno V.; Notario-Pacheco B. (Taylor and Francis Ltd, 2018) -
Exercise program and blood pressure in children: The moderating role of sedentary time
García-Hermoso A.; Hormazábal-Aguayo I.; González-Calderón N.; Russell-Guzmán J.; Vicencio-Rojas F.; Chacana-Cañas C.; Urrutia-Reyes I.; Ramírez-Vélez R.; Alonso-Martinez A.M.; Izquierdo M.; Fernández-Vergara O. (Elsevier Ltd, 2020) -
Efficacy and Tolerability of the Combination Valsartan/Hydrochlorothiazide Compared with Amlodipine in a Mild-to-moderately Hypertensive Brazilian Population
Franco, Roberto J.S.; Goldflus, Suely; McQuitty, Mari; Oigman, Wille