Search
Now showing items 1-10 of 128
Orbital Implants Insertion to Improve Ocular Prostheses Motility
(Lippincott Williams & Wilkins, 2010-05-01)
The objectives of this study were, through a literature review, to point the differences between orbital implants and their advantages and disadvantages, to evaluate prosthesis motility after orbital implants are inserted, ...
Cohesive silicone gel implants with smooth, textured or polyurethane-coated surface to restore volume in eviscerated sockets
(Taylor & Francis Inc, 2018-01-01)
The purpose of this article is to evaluate the three different surface coating on cohesive silicone gel implants in eviscerated rabbit eye sockets. Forty-five albino rabbits underwent right eye evisceration and received ...
Gelatinous polyethylene in the treatment of the anophthalmic cavity
(2002-08-23)
PURPOSE: Gelatinous polyethylene (GP) has been used as an orbital implant to evaluate volume maintenance and tissue reaction in the anophthalmic socket in a rabbit model. METHODS: Twenty-eight Norfolk white rabbits underwent ...
Extrusão dos implantes em portadores de cavidade anoftálmica
(2007-09-01)
Purpose: To evaluate the characteristics of patients with anophthalmic cavity who developed sphere extrusion. Methods: A retrospective observational study was done evaluating 37 patients with anophthalmic cavity and sphere ...
Anophthalmic socket: Choice of orbital implants for reconstruction
(2015-01-01)
This literature review considers the treatment of an anophthalmic socket and the controversial aspects of the implants used to restore the lost volume after enucleation or evisceration, including the different materials ...
Is There An Ideal Implant For Orbital Reconstructions? Prospective 64-case Study
(Churchill LivingstoneEdinburgh, 2016)
Avaliação de um novo implante intra-orbitário: resultados preliminares
(Conselho Brasileiro de Oftalmologia, 2003-01-01)
PURPOSE: To describe a new orbital implant, with an original shape, the surgical technique adapted for its implantation and preliminary results. METHODS: The authors describe the surgical technique performed in 22 patients, ...
Orbital Implants Insertion to Improve Ocular Prostheses Motility
(Lippincott Williams & Wilkins, 2013)
Chronic Inflammation in an Anophthalmic Socket due to a Room Temperature Vulcanized Silicone Implant
(2016-01-01)
Two case reports are used to illustrate the signs and symptoms, complications and treatments of chronic socket inflammation due to intraorbital implants. The ophthalmic examination, surgeries and treatments are documented. ...